Product Manual

Hanshow ESL Controller HS_C09959 Product Manual V1.0.2
5 Hanshow Copyright Reserved ©
Zhejiang Hanshow Technology Co., Ltd.
2.2 Physical interface
HS_C09959’s physical interfaces are as shown in Figure 2-1, and each interface’s
function is illustrated in Table 2-2.
Figure 2-1 External interface of HS_C09959
Table 2-2 Function description for each interface
No.
Interface name
Description
1
Reset button
Press and hold: restore factory settings, press this
button for more than 5 seconds,
Press: HS_C09959 could switch between
enabling DHCP and fixed IP (192.168.1.199),
after triggering the function, it will invalid to press
in 30 seconds. For detailed information, refer to
the section of 4.1.
2
USB interface
USB2.0 interface, output current is less than
5V/250mA.
3
Power interface
Can connect to DC power adapter that is standard
12V/1A adapter provided by Hanshow
4
CONSOLE interface
Professionals debug device interface
5
POE interface
Adaptive 10M/100M Ethernet, and support IEEE
802.3at/af standard Ethernet power supply
6
Light
LED indicator is used for system status. For more
information, refer to section of 2.3
7
Light
LED indicator is used for network status. For more