Installation Manual

Relationship between cable diameter (24V AC) and transmission distance 17
Relationship between Cable
Diameter (12V DC) and Transmission
Distance
The recommended transmission distances are for reference only, and the actual conditions
shall prevail.
The chart below gives the maximum transmission distance of cables with certain diameters
when the 12V DC power source voltage lose rate is bellow 10%.
For cameras powered by direct current, the maximum voltage loss rate allowed is 10%.
Cables mentioned in the table below are copper cables ( the resitivity of copper ρ =
0.0175Ω mm
2
/m)
Transmission
power (W)
Cable diameter (mm)
0.8000 1.000 1.250 2.000
Transmission distance Feet (m)
5
122.13 (37.23)
190.83 (58.16)
298.17 (90.88)
763.31 (232.66)
10
61.06 (18.61)
95.41 (29.08)
149.08 (45.44)
381.66 (116.33)
15
40.71 (12.41)
63.61 (19.39)
99.39 (30.29)
254.44 (77.55)
20
30.53 (9.31)
47.71 (14.54)
74.54 (22.72)
190.83 (58.16)
25
24.43 (7.45)
38.17 (11.63)
59.63 (18.18)
152.66 (46.53)
30
20.35 (6.20)
31.80 (9.69)
49.69 (15.15)
127.22 (38.78)
35
17.45 (5.32)
27.26 (8.31)
42.60 (12.98)
109.04 (33.24)
40
15.27 (4.65)
23.85 (7.27)
37.27 (11.36)
95.41 (29.08)
45
13.57 (4.14)
21.20 (6.46)
33.13 (10.10)
84.81 (28.85)
50
12.21 (3.72)
19.08 (5.82)
29.82 (9.09)
76.33 (23.27)
55
11.10 (3.38) 17.35 (5.29) 27.11 (8.26) 69.39 (21.15)
60
10.18 (3.10)
15.90 (4.85)
24.85 (7.57)
63.61 (19.39)
65
9.39 (2.86)
14.68 (4.47)
22.94 (6.99)
58.72 (17.90)
70
8.72 (2.66)
13.63 (4.15)
21.30 (6.49)
54.52 (16.62)
75
8.14 (2.48)
12.72 (3.88)
19.88 (6.06)
50.89 (15.51)
80
7.63 (2.33)
11.93 (3.64)
18.64 (5.68)
47.71 (14.54)
85
7.18 (2.19)
11.23 (3.42)
17.54 (5.35)
44.90 (13.69)
90
6.78 (2.07)
10.60 (3.23)
16.56 (5.05)
42.41 (12.93)
95
6.43 (1.96)
10.04 (3.06)
15.69 (4.78)
40.17 (12.25)
100
6.11 (1.86)
9.54 (2.91)
14.91 (4.54)
38.17 (11.63)