Users Manual Part 1

137
Figure 5-53 Manual add
Step 4 Configure the parameters.
The parameters might vary depending on the manufacturer that you select.
Table 5-14 Remote channel parameters
Parameter
Description
Channel
Select the channel that you want use on the Device to connect the
remote device.
Manufacturer
Select the manufacturer of the remote device.
IP Address
Enter the IP address of the remote device.
RTSP Port
Enter the RTSP port number.
The default value is 554.
HTTP Port
Enter the HTTP port number. The default value is 80.
TCP Port
The default value is 37777. You can enter the value as needed.
Username
Enter the username of the remote device.
Password
Enter the password of the user
for the remote device.
Total Channels
Click
Connect to get the total number of channels of the remote
device.
Remote CH No.
Enter the remote channel number of the remote device.
Decode Strategy
Select
Default, Realtime, or Fluent.
Protocol Type
If the remote device is added through private protocol, the
default type is TCP.
If the remote device is added through ONVIF protocol, the
system supports Auto, TCP, UDP, or MULTICAST.
If the remote device is added through other manufacturers, the
system supports TCP and UDP.