User's Manual
82
Using V1 and V2 might cause data leakage, and V3 is recommended.
In Trap Address, enter the IP address of the PC that has MIB Builder and MG-SOFT MIB
Browser installed, and leave other parameters to the default.
Table 5-19 Description of SNMP parameters
Parameter
Description
SNMP Port
The listening port of the software agent on the Device.
Read Community, Write
Community
The read and write community string that the software agent
supports.
The name must consist of numbers, letters, underlines and
strikethroughs.
Trap Address
The target address of the Trap information sent by the software
agent on the Device.
Trap Port
The target port of the Trap information sent by the software agent
on the Device.
Keep Alive
After you select the checkbox, the Device can send data packet to
ensure continuous network connection.
Read-only Username
Set the read-only username used to access the Device, and it is
public by default.
The name must consist of numbers, letters or underlines.
Read/Write Username
Set the read/write username used to access the Device, and it is
public by default.
The name must consist of numbers, letters or underlines.
Authentication Type
You can select MD5 or SHA. The default type is MD5.
Authentication Password
It cannot be less than 8 digits.
Encryption Type
It is CBC-DES by default.
Encryption Password
It cannot be less than 8 digits.
Step 3 Click Save.
Result
View device configuration through MIB Builder or MG-SOFT MIB Browser.
1. Run MIB Builder and MG-SOFT MIB Browser.
2. Compile the two MIB files with MIB Builder.
3. Load the generated modules with MG-SOFT MIB Browser.
4. Enter the IP address of the Device you need to manage in the MG-SOFT MIB Browser, and then
select version to search.
5. Unfold all the tree lists displayed in the MG-SOFT MIB Browser, and then you can view the
configuration information, video channel amount, audio channel amount, and software version.