User's Manual
38
Parameter
Description
Brightness
Set the overall image brightness. The larger the value is, the brighter the image
will be. The value ranges from 0 to 100.
Contrast
Set the image contrast. The larger the value is, the greater the contrast will be.
The value ranges from 0 to 100.
Saturation
Set the intensity of colors. The larger the value is, the brighter the colors will
be. The value ranges from 0 to 100.
Chroma CNT
The larger the value, the higher suppression on image colors. The value ranges
from 0 to 100.
This parameter takes effect only when the Device is in the environment with
low luminance.
Sharpness
Set the sharpness of picture edges. The larger the value is, the more obvious
the edge will be. The value ranges from 0 to 100.
If the value is too large, there might be image noise. Set the value according to
the actual condition.
Sharpness CNT
The larger the value is, the stronger the sharpness CNT will be. The value
ranges from 0 to 100.
This parameter takes effect only when the Device is in the environment with
low luminance.
Gamma
Change image brightness through non-linear tuning to expand the dynamic
display range of images. The larger the value is, the brighter the image will be.
The value ranges from 0 to 100.
Flip
Monitoring videos can be flipped over. There are two options.
● 0°: The monitoring video is normally displayed. It is 0° by default.
● 180°: The monitoring video is flipped over.
EIS
Electronic image stabilization (EIS) is used to effectively solve the problem of
image shaking during use, thus presenting clearer images. It is Off by default.
● This function is available on select models.
● This parameter takes effect only when the Device is in the environment
with low luminance.
● Optical image stabilization and electronic image stabilization cannot be
enabled at the same time.
Picture Freeze
After you select On, the image at the called preset is displayed directly if you
call a preset or tour, and no images during the rotation of the Device are
displayed.
Step 3 Click Save.
5.1.1.1.2 Exposure
You can control the amount of light per unit area reaching the electronic image sensor by adjusting
parameters on the Exposure interface.
Step 1 Select Setting > Camera > Conditions > Conditions > Exposure.