User's Manual

111
Figure 5-83 Area setting
Table 5-26 Description of area setting parameter
Parameter
Description
Name
The default names are Region1, Region2, Region3 and Region4, and
the names can be customized.
Sensitivity
Sensitivity to brightness change. The higher the sensitivity is, the
easier the motion detection event will occur.
You can set different sensitivities for each region, with values ranging
from 0 to 100, and 30 to 70 is recommended.
Threshold
Detect the relation between the object and the region. The smaller the
threshold is, the easier the motion detection will occur.
Set different thresholds for each region, with values ranging from 0 to
100, and 1 to 10 is recommended.
Waveform graph
The red line indicates that motion detection is triggered, and the green
line indicates that it is not triggered.
Remove All
Remove all detection regions.
Delete
Delete the detection region of the selected color block.
Other parameters
Table 5-27 Description of video detection parameter
Parameter
Description
Anti-Dither
The system records only one motion detection event within the defined
period. The value range is 0100 s.
Enable Manual
Control Trigger
After you enable the function, the motion detection events that occur
when you control the PTZ manually will be excluded. In this way, you can
reduce the false alarm rate of such events.