User's Manual

User’s Manual
116
Try to reduce the complexity of monitoring scenes. It is not recommended to enable IVS in
scenes with dense targets and frequent light changes.
Try to avoid the following scenes: scenes with reflective surfaces such as glass, bright
ground or water; scenes that disturbed by tree branches, shadows or winged insects;
scenes that against light or under direct light exposure.
Before using the function, you need to set presets in advance. For setting methods, see
"5.3.2.1 Preset."
Rule Config
1. Select
Setting
>
Event
>
IVS
>
Rule Config
.
Figure 5-90 Add smart rules
2. Select the presets to be configured with smart rules.
3. Click to add smart rules.
Double-click rule type to modify the type of rules.
4. Click
Save
.
5.5.5.1 Tripwire
Alarms are triggered when the target crosses the warning line in the defined direction. It
requires certain stay time and moving space for the target to be confirmed, so you need to
leave some space at both sides of the warning line during configuration and do not draw it
near obstacles.
Applicable scenes: Scenes with sparse targets and no occlusion between targets, such as
perimeter protection of unattended areas.
Procedure
Step 1 Select
Tripwire
from the
Rule Type
list.