Parameter
Description
If alarm input type of the alarm device you purchased is NO, then you
should select NO; otherwise you should select NC.
Fire Link Enable
If fire link is enabled the terminal will output alarms when fire alarms
are triggered. The alarm details will be displayed in the alarm log.
Alarm output and access link are NO by default if fire link is enabled.
Alarm Output
Enable
The relay can output alarm information (will be sent to the
management platform) if the Alarm Output is enabled.
Duration (Sec.)
The alarm duration, and the range is 1–300 seconds.
Alarm Output
Channel
You can select an alarm output channel according to the alarming
device that you have installed.
Access Link
Enable
After the Access Link is enabled, the terminal will be normally open or
normally closed when there are input alarm signals.
Channel Type
There are two options: NO and NC.
Click OK, and then the configuration is completed. Step 3
The configuration on the web will be synchronized with the configuration in the client if the
terminal is added to a client.
4.4.2 Alarm Log
You can view the alarm type and time range in the Alarm Log interface.
Select Alarm Linkage > Alarm Log. Step 1
Alarm log Figure 4-9
Select a time range and alarm type, and then click Query. Step 2