User's Manual

6
Port
Cable color
Cable name
Description
White and
purple
PUSH2
Door open button of door No.2
White and
green
GND
Connected to the common GND port.
White and
brown
ALARM1
Alarm 1 input port.
CON3
Black and
blue
GND
Connected to the common GND port.
Black and
gray
SR1
Used for door contact detection.
Black and
green
PUSH1
Door open button of door No.1
Black and
purple
DOOR1_NC
Lock control normally closed port.
Black and
brown
DOOR1_COM
Lock control common port.
Black and
yellow
DOOR1_NO
Lock control normally open port.
Installation Notes 2.2
If there is light source 0.5 meters away from the device, the minimum illumination should
be no less than 100 Lux.
It is recommended that the device is installed indoors, at least 3 meters away from
windows and doors and 2 meters away from lights.
Avoid backlight and direct sunlight.
Ambient Illumination Requirement
Ambient illumination requirement Figure 2-2
Temperature Monitoring Requirement
It is recommended to install the temperature monitoring unit in an indoor windless
environment (a relatively isolated area from the outdoor), and maintain the ambient
temperature at 15°C to 32°C .