User's Manual
26
Alarm linkage
Click to modify the alarm linkage parameters.
Change alarm linkage parameters
Table 3-2 Alarm linkage parameter description
Parameter
Description
Alarm Input
You cannot modify the value. Keep it default.
Name
Enter a zone name.
Alarm Input Type
Select the type according to the alarm input type of the alarm
device you have purchased.
NO: The circuit of the alarm device is normally open, and it
closes when an alarm is triggered.
NC: The circuit of the alarm device is normally closed, and it
opens when an alarm is triggered.
Fire Link Enable
If enabled, the device will output fire alarms when triggered. The
alarm details will be displayed in the alarm log.
Alarm output and access link are NO by default if fire link is
enabled.
AlarmOutput Enable
After enabling alarm output, the relay can output alarm
infromation.
Duration (Sec.)
Alarm duration. It ranges from 1 s through 300 s.
AlarmOutput Channel
The device has only one output channel. Select the one according
to your alarm device.
Access Link Enable
If enabled, the device will be normally on or normally closed when
there are input alarm signals.