User's Manual

Table 5-1 Installation items
No. Item name
1 PIR
2 ST3 × 18 mm self-tapping screw
3 Attachment panel
4 Expansion bolt
5 Wall
Step 1 Drill 4 holes in wall according to the hole positions of the
attachment panels.
Step 2 Put the expansion bolts into the holes.
Step 3 Align the screw holes on the plate with the expansion bolts.
Step 4 Fix the attachment panels with ST3 × 18 mm self-tapping
screws.
Step 5 Put the PIR into the attachment panel from top to bottom.
6
PIR Configuration
You can view and edit general information of the PIR.
6.1 Configuring the PIR
On the Hub interface, select the PIR as needed from the accessory
list, and then you can configure the parameters of the PIR.
Table 6-1 PIR parameter description
Parameter Description
Device Configuration
View device name, type, SN and device model.
Edit device name, and then tap Save to save
configuration.
Area Select the area to which the PIR is assigned.
24 H Protection Zone
The accessory located in the 24 h protection zone
is always active whether the security system is
configured in the armed mode or not.
Home Mode
Enable the home mode, and then the selected
accessories under the hub will be armed.
Delay Mode under Home
Mode
Enable the Delay Mode under Home Mode, the
selected accessory under the hub will be armed
and the alarm will not be triggered until the end of
customized delay time.
Only enable Home Mode first can Delay Mode
under Home Mode take effect.
Delay Time
The system provides you with time to leave or
enter the protection zone without alarm.
Select from 0 s to 120 s.
The arming mode will be effective after the delay
time.
Sensitivity
Sensitivity level during a shock alarm.
Select from low, medium and high.
Alarm-speaker Linkage
When an alarm is triggered, the accessories will
report the alarm events to the hub and alert with
siren.
Alarm-video Linkage
When an alarm is triggered, the accessories will
report the alarm events to the hub and then will be
linked with videos.
Parameter Description
Video Channel Select the video channel as needed.
Signal Strength Detection Test the current signal strength.
Detector Test
Tap Start Detection to test the status of the
detector.
Transmit Power
Select from high, low, and automatic.
The higher the transmission power, the
farther the transmission and the higher power
consuming.
Cloud Update Update online.
Delete
Delete the online accessory.
Go to the Hub interface, select the accessory from
the list, and then swipe left to delete it.
6.2 Viewing Status of the PIR
On the Hub interface, select the PIR as needed from the accessory
list, and then tab
to view the status of the PIR.
Table 6-2 Status
Parameter Description
Temperature The temperature of the environment.
Signal Strength
The signal strength between the hub and the PIR.
: Ultra low.
: Low.
: Moderate.
: High.
: No.
Battery Level
The battery level of the PIR.
: Fully charged.
: Sufficient.
: Moderate.
: Insufficient.
Anti-tampering Status Anti-tampering status of the PIR.
Online Status
Online and offline status of the PIR.
: Online.
: Offline.
Entrance Delay Time
Exit Delay Time
Entrance and exit delay time.
Sensitivity Sensitivity level during a shock alarm.
24 H Protection Zone
Status
Active status of the 24 h protection zone.
: Enable.
: Disable.
Program Version The program version of PIR.