Data Sheet
DB SUBMINIATURE SWITCH
CONTINUED
Electrical rating and operating life ❷
Electrical rating
according to
Electrical life
(operations)
Mechanical
life
Operating
force
Housing
mark
Code
EN 61058-1 UL 1054 acc. to EN acc. to UL max. (cN)
6A 250V AC 5A 125 – 250V AC 10,000 6,000 15 x 10
6
150 DB 1 1
10 (1.5)A, 250V AC 10.1A, 125 – 250AC,
1/4 HP, 125V AC
10,000 6,000 10 x 10
6
250 DB 2 2
0.1A, 250V AC 0.1A 125–250V AC 50,000 100,000 15 x 10
6
150 DB 3 3
4A, 250V AC 4A, 125 – 250V AC 50,000 6,000 15 x 10
6
90 DB 4 4
1A, 250V AC 1A, 125 – 250V AC 50,000 6,000 15 x 10
6
70 DB 5* 5*
10 (3)A, 250V
AC 10.
1A, 125
– 250V A
C,
1/4 HP, 125V AC
10,000
6,000 10 x 10
6
280 DB L L
6 (2)A, 250V AC 5A, 125 – 250V AC 50,000 6,000 15 x 10
6
150 DB O O
Special versions with lower ratings upon request * Only T85
Switching parameters
Model Type Max. operating
force
(cN)
Max.
pretravel
(mm)
Min.
overtravel
(mm)
Differential
travel
max.(mm)
Max. rest
position
(mm)
Operating
point
(mm)
Length
actuator
(mm) ± 0.8
Spherical-head
actuator or
actuator with
radius, without
auxiliary actuator
DB5
DB1/O/3
DBL
DB2
DB4
70
150
280
250
90
1.0
1.0
1.0
1.0
1.0
0.6
0.6
0.6
0.6
0.6
0.1
0.1
0.15
0.1
0.1
9.3
9.3
9.3
9.3
9.3
8.4
0.3
8.4
0.3
8.4
0.3
8.4
0.3
8.4
0.3
–
–
–
–
–
Terminal type ❹
Terminal type Code
Q.C. terminal 2.8 x 0.5mm, straight B1
Solder terminal short A1
PCB terminal 1.3 x 0.5mm, straight C1
PCB terminal 0.6 x 0.5mm, straight D1
PCB terminal 0.6 x 0.5mm, RH side* D2
PCB terminal 0.6 x 0.5mm, LH side* D3
PCB terminal 0.6 x 0.5mm, RH side** D4
PCB terminal 0.6 x 0.5mm, LH side** D5
* With location pins
** Without location pins
Auxiliary actuator ❺
Model Mounting
point
Length Order code* Code
Without lever,
spherical head
–––AA
Without lever,
radius shape
–––BA
Straight RM rear
FM front
4.8
7
42
7
9.4
43.5
614-01232
614-01233
614-01234
614-01232
614-01233
614-01234
LB
LC
LD
MB
MC
MD
Roller RM rear
FM front
2.5
4.7
39.7
4.7
7.1
41.2
714-00260
714-00261
714-00262
714-00260
714-00261
714-00262
RB
RC
RD
TB
TC
TD
Simulated roller RM rear
FM front
2.5
4.7
39.7
4.7
7.1
41.2
614-01237
614-01238
614-01239
614-01237
614-01238
614-01239
SB
SC
SD
UB
UC
UD
Plastic, straight RM rear
FM front
7
14
9.4
16.2
614-01247
614-01253
614-01247
614-01253
WB
WC
GB
GC
Plastic roller RM rear
FM front
5.2
7.3
714-00299
714-00299
ZB
OB
Plastic
simulated roller
RM rear
FM front
5.6
7.9
614-01249
614-01249
VB
HB
* For retrofitting
Electrical rating at DC voltage
Please see our technical specification for DC currents (TS-0002)
which is available upon request.
For detailed information please note the technical specifications which you can find in the download section of our website www.switches-sensors.zf.com.