Datasheet
Coil I Coil II
RELAY ORDERING DATA
SINGLE SIDE STABLE
COIL SPECIFICATIONS
Nominal Coil Must Operate Max Continuous Coil Resistance
ORDER NUMBER
VDC VDC VDC ± 10%
3 2.3 7.5 64.3 AZ850–3
5 3.8 12.5 178 AZ850–5
6 4.5 15.0 257 AZ850–6
9 6.8 22.5 579 AZ850–9
12 9.0 30.0 1,028 AZ850–12
24 18.0 48.0 2,880 AZ850–24
48 36.0 80.0 7,680 AZ850–48*
BISTABLE (LATCHING) SINGLE COIL
COIL SPECIFICATIONS
Nominal Coil Must Operate Max Continuous Coil Resistance ORDER NUMBER
VDC VDC VDC ± 10%
3 2.3 8.7 90 AZ850P1–3
5 3.8 14.5 250 AZ850P1–5
6 4.5 17.4 360 AZ850P1–6
9 6.8 26.1 810 AZ850P1–9
12 9.0 34.8 1440 AZ850P1–12
24 18.0 57.6 3840 AZ850P1–24
BISTABLE (LATCHING) TWO COIL
COIL SPECIFICATIONS
Nominal Coil Must Operate Coil Resistance
ORDER NUMBER
VDC VDC VDC
3 2.3 6.0 45 45 AZ850P2–3
5 3.8 10.0 125 125 AZ850P2–5
6 4.5 12.0 180 180 AZ850P2–6
9 6.8 18.0 405 405 AZ850P2–9
12 9.0 24 720 720 AZ850P2–12
24 18.0 40 1,920 1,920 AZ850P2–24
Max Continuous
VDC
11/28/11
MECHANICAL DATA
Dimensions in inches with metric equivalents in parentheses. Tolerance: ±0.010"
*Not UL Approved
AZ850
[0.69]
.027
PC BOARD LAYOUT
[2.54]
Stripe on top of relay
of pins 1 & 10
[2.54]
WIRING DIAGRAMS
[14.0]
.551
BISTABLE (LATCHING) TWO COIL
10x.138
10 x .032
[0.81]
4 x .100
VIEWED TOWARDS TERMINALS
Reset Coil
867910
6710 9 8
Watch for polarity
VIEWED TOWARDS TERMINALS
(-)
DEENERGIZED OR RESET CONDITION
RESET CONDITION
Watch for polarity
45123
SINGLE SIDE STABLE
10x.020
4x.100
(+)
indicates the position
Diagrams show the "reset"
position before energized
with polarity as shown.
[7.63]
[3.5]
.300
[0.25]
.010
[0.25]
[5.0]
.197
(+)
21
(+)
[0.51]
.300
[7.62]
.075
[1.90]
10x.010
[9.00]
.354
(-)
Set Coil
(-)
354