5. When the login screen shown in Figure 23 opens, enter the Username: root and
the Password: dbps
, then click on the Login button. The Home screen for the Digi
Connect ME opens.
Figure 23: Login Screen of Digi Connect ME
6. In the column on the left of the screen, under the heading Configuration, select the
Network option. The Network screen shown in Figure 24 opens.
Figure 24: Assign the New IP Address
7. Make sure the “Use the following IP address:” radio button is selected and fill in
the new IP Address: and Subnet Mask: for the unit. (The subnet will almost
always be 255.255.255.0) Whether or not you need to enter a Default Gateway:
Caution! Never use the Factory Default Settings option. Doing so
changes many parameters set at Zetron that will negatively
impact network connection reliability and performance.
!