Specifications
Configuring Station Transponder Units
72 025-9581M
Figure 20: The Inputs Menu
This menu shows the current state of each sense input, polarity (Active State), the state
transition necessary to reset the relay (if so configured; see “Relays” Menu on page 69),
and debounce time. The states (open and closed) are in reference to the state of a contact
closure between the sense input negative lead and its ground input (see Sense Inputs on
page 170). Selecting one of the sense inputs from this menu displays the menu in Figure
21. The paragraphs following the figure give a brief description of the parameters in this
menu.
Figure 21: Sense Input Parameter Selection Menu
Active Polarity
This parameter is found in the Sense Input Parameter Selection Menu. It holds the active
polarity of the selected sense input. Selecting this parameter toggles the polarity shown
under Current Setting.