Specifications
Creating the System Servers
54 025-9581M
CAD Input Selection
Type
This sets the type of CAD license that the translator checks for when the service is
started. Choose from Serial, TriTech_Serial, or XML.
CAD Serial Communications
Port
The CAD Translator uses a serial port when it is supporting the Model 26 Serial
CAD protocol. This field holds the COM port on the FSA Server computer used by
the serial data link coming from the CAD system. It will typically be one of the first
four COM ports on the server machine.
Baud Rate
This is the baud rate used by the CAD-FSA serial connection. It defaults to 9600. It
should be set to whatever speed the connection is using.
FSA Communications
Host
This parameter is for the IP address of the computer running the FSA Server. In
most cases, it will be the same machine that the CAD Translator is running on.
Port
This is the port used by the FSA Server. It defaults to 43001 and should not be
changed.
Note The default setting is Serial. If you have the XML CAD license, set
this parameter to XML.