Specifications
141
Model 26 Backup in a VoIP System
6. If item {4} Communication Mode is not set to VOX, enter a “4” to open the
Communication Mode sub menu and enter a “2” to set the unit to use VOX. When
finished, press “e” to return to the Station Configuration menu. For more
information on this sub menu, see “Communications Mode” Menu on page 66.
7. Enter a “5” to select {5} Keyup Delay. Set this parameter to the necessary value to
ensure that the unit waits until the transmitter is fully keyed before sending data.
Systems using a repeater will require a longer delay. One to two seconds is usually
a good starting point for this parameter. When finished, press “e” to return to the
Station Configuration menu.
8. Enter a “6” to select {6} Retry Period. Set this parameter to 10 seconds to start
with and then adjust it later as necessary to optimize system performance. When
finished, press “e” to return to the Station Configuration menu. For more
information on this parameter, see Retry Period on page 65.
9. Enter an “e” to return to the main menu. Then enter a “5” to open the {5} PA
Options menu.