Product manual
Data Level Packet Details
79
Model 26 Response: Low Level ACK/NAK, High Level ACK/NAK
Seq Num High Level Sequence Number: , Range 01 - 255
Cmd Num Command Number = 4
Text Chn Text Channel, must be 0
Num Bytes Number of Bytes of ASCII text, Range 1-250 (n)
Print Data Byte 8 first byte of ASCII text
Byte n+7 last byte of ASCII text
CAD Command 5: Define Text Channel (Dedicated)
Byte # 1 2 3 4 5 6 7,8 .~.~
LABEL STX LL SEQ# HL SEQ# Resp. Num Numb Stns Text
Channel
Station
Address
Range 02 00 or FF 01 to FF
05
01 to 0F 00 0000 to 03FF
Example 02 00 05
05
0N 86 0123
.~.~ 9 10,11 12 13,14 15 ~ ~ 3N+9 3N+10
# of Copies Station
Address
# of Copies Station
Address
# of Copies etc. ETX CK SUM
1-15 0000 to
03FF
1-15 0000 to
03FF
1-15 etc. 03 00 to FF
15 0116 15 0147 15 etc. 03 XX
Model 26 Response: Low Level ACK/NAK, High Level ACK/NAK
Seq Num High Level Sequence Number, Range 1 - 255
Cmd Num Command Number = 5
Num Stns Number of Stations included in this channel
(<= 16, 1 for All Stations)
Text Chn Text Channel, currently must be 0
Station Address Range: 1 – 1023 and 2048 = All Stations
Num Cps Number of Copies, Range 1 - 15
Note
The number of Station Address/Number of Copies pairs must be
equal to the Number of Stations given in byte 5 and must not
exceed 16.