Product manual
CAD Interface Installation
78 025-9158L
CAD Response: Low Level ACK/NAK
Seq Num High Level Sequence Number = 00
Resp Num Response Number = 10
Station Address Range: 1-1023 0 = System
Alarm Type:
0 = Manual Alarm (Emergency)
1 = Reset
2 = Watch Dog
3 = Clock Monitor Fail
4 = Illegal Instruction
5 = Illegal Interrupt
6 = Communication Error
7 = Communication Restored
8 = Subsystem Communication Error
9 = Subsystem Communication Restored
10 = Manual Alarm Clear (Emergency)
11-255 = Not Used
Data -> Depends on Alarm Type (Not currently defined)
CAD Text Control Packets
The following paragraphs describe the text related packets sent by the CAD.
CAD Command 4: Send Text
Byte # 1 2 3 4 5,6 7 .~.~
LABEL STX LL SEQ# HL SEQ# Resp. Num Text Chan # Num of Bytes
Range 02 00 or FF 01 to FF
04
00 01 to FA
Example 02 FF 04
04
00 86
.~.~ 8 9 n+5 n+6 n+7 n+8 n+9
Print Data More Data More Data More Data Last Data ETX CK SUM
00 to FF 00 to FF 00 to FF 00 to FF 00 to FF 03 00 to FF
XX XX XX XX XX 03 XX