Product manual

Data Level Packet Details
77
Unit State Codes:
0 = Available In
1 = Available Out
2 = Responding
3 = On Scene
4 = Transporting
5 = Facility
6 = Conditional Out of Service
7 = Out of Service
Sns Inps ... Sense Inputs (Bit Levels: 0 = Inactive, 1 = Active)
MSB = 7 Not Used
6 Not Used
5 Not Used
4 Not Used
3 Sense Input 4
2 Sense Input 3
1 Sense Input 2
LSB = 0 Sense Input 1
Stn State ... Station Status
MSB = 7 Alert State: 0 = Off, 1 = On
6 Not Used
5 Not Used
4 Not Used
3 Not Used
2 Not Used
1 Emergency: 0 = Off, 1 = On
LSB = 0 All Station: 0 = Off, 1 = On
Model 26 Response 10: Alarm Status
Byte # 1 2 3 4 5,6 7 8 9 10
LABEL STX LL SEQ# HL SEQ# Resp. Num Stn Addr. Alarm Data ETX CK SUM
Range 02 00 or FF 00 0A 0001 to
03FF
00 to
0A
xx 03 00 to FF
Example 02 00 00 0A 02F6 06 00 03 F8