Product manual
CAD Interface Installation
76 025-9158L
CAD Response: Low Level ACK/NAK
HLSeq# High Level Sequence Number = 00 if unsolicited, else 01/FF
Resp # Response Number = 12
Station Address Range: 1 - 1023
Stn Mode Station Mode bits (1=On/Active 0=Off/Inactive):
MSB = 7 Comm Error
6 Station Mic
5 Station PA
4 Printer Printing
3 Printer Ready
2 Not Used
1 Not Used
LSB = 0 Not Used
Unit Enb A bit field indication the state of the Unit Enables:
Active Level for bits: 0 = Disabled 1 = Enabled
MSB = 7 Not Used
6 Not Used
5 Not Used
4 Not Used
3 Unit 4 Enable state
2 Unit 3 Enable state
1 Unit 2 Enable state
LSB = 0 Unit 1 Enable state
Unit N St Unit State, where N is unit number (bytes 7 - 10)
Each of these bytes is defined as follows:
MSB = 7 Alert State: 0 = Off, 1 = On
6 Not Used
5 Not Used
4 Not Used
3 Not Used
2 Unit State Code
1 Unit State Code
LSB = 0 Unit State Code