Product manual

Data Level Packet Details
75
Model 26 Response 3(5): Station Unit Enables Status (Fmt 5)
Byte # 1 2 3 4 5,6 7 8 11 12
LABL STX LL
SEQ#
HL
SEQ#
Resp
Num
Station
Address
Fmt
Nmbr
Unit
Enable
ETX CKSUM
Range 02 00 or
FF
00
03
0001 to
03FF
05
00 to
0F
03 xx
Exmpl 02 00 00 (10)03 0008
05
07 03 D9
CAD Response: Low Level ACK/NAK
HLSeq# High Level Sequence Number = 00
Resp Num Response Number = 03
Station Address Range: 1 - 1023
Unit Enb A bit field indication of the state of the Unit Enables:
MSB = 7 Not Used
6 Not Used
5 Not Used
4 Not Used
3 Unit 4 Enable State
2 Unit 3 Enable State
1 Unit 2 Enable State
LSB = 0 Unit 1 Enable State
Active Level for bits: 0 = Disabled, 1 = Enabled
Model 26 Response 12: Station Full Status
Byte # 1 2 3 4 5,6 7 8 .~.~
LABEL STX LL SEQ# HL SEQ# Resp
Num
Station
Address
Station
Mode
Unit
Enable
Range 02 00 or FF 00 to FF
0C
0001 to 03FF 00 to F8 00 to FF
Example 02 FF 00
0C
0109 20 07
.~.~ 9 10 11 12 13 14 15 16
Unit #1
Status
Unit #2
Status
Unit #3
Status
Unit #4
Status
Sense
Inputs
Station
Status
ETX CK SUM
00 to 87 00 to 87 00 to 87 00 to 87 00 to 0F 00 to 83 03 xx
87 00 03 06 03 02 03 2E