Product manual

CAD Interface Installation
74 025-9158L
Model 26 Response 3(3): Station Input Status (Fmt 3)
Byte # 1 2 3 4 5,6 7 8 9 10 11
LABL STX LL
SEQ#
HL
SEQ#
Resp
Num
Station
Address
Fmt
No.
Input
Nmbr
State ETX CK
SUM
Range 02 00 or
FF
00
03
0001 to
03FF,0800
03 01 to
04
00 or
NZ
03 xx
Exmpl 02 00 00 (10)03 0008 (10)03 (10)02 78 03 48
CAD Response: Low Level ACK/NAK
HLSeq# High Level Sequence Number = 00
Resp Num Response Number = 3
Station Address Range: 1 - 1023
Input Num Sense Input Number, Range: 1 - 4
State Input State: Zero = Input off, Non-Zero = Input on
Model 26 Response 3(4): Station Misc. Bits Status (Fmt 4)
Byte # 1 2 3 4 5,6 7 8 9 10 11 12 13
LABEL STX LL
SEQ#
HL
SEQ#
Resp
Num
Stn
Addr
Fmt
No.
MIC PA Prtr
Prtg.
Prtr
Rdy
ETX CK
SUM
Range 02 00 or
FF
00
03
0001 to
03FF
04
00 or
NZ
00 or
NZ
00 or
NZ
00 or
NZ
03 xx
Exmpl 02 FF 00 (10)03 0009
04
00 FF 00 44 03 9D
CAD Response: Low Level ACK/NAK
HLSeq# High Level Sequence Number = 00
Resp Num Response Number = 3
Station Address Range: 1 - 1023
Mic Microphone State, Zero = Off, Non-Zero = On
PA PA State, Zero = Off, Non-Zero = On
Prn Ptg Printer Printing, Zero = No, Non-Zero = Yes (Not Used in
Shared Sys)
Prn Rdy Printer Ready, Zero = Not Ready, Non-Zero = Ready