Product manual

Data Level Packet Details
73
Model 26 Response 3(1): Station and Unit Status (Fmt 1)
Byte # 1 2 3 4 5,6 7 8 9 10 11 12
LABEL STX LL
SEQ#
HL
SEQ#
Resp
Num
Station
Address
Fmt
No.
Unit
Nmbr
State Alert ETX CK
SUM
Range 02 00 or
FF
00
03
0001 to
03FF
01 01-04,
07
00 to
07
00 or
NZ
03 xx
Example 02 FF 31 (10)03 0007
01
07 00 55 03 59
CAD Response: Low Level ACK/NAK
HLSeq# High Level Sequence Number = 00 if unsolicited, else 01/FF
Resp Num Response Number = 03
Station Address Range: 1 - 1023
Fmt Nmbr Format Number = 01
Unit Num Unit Number, Range: 1 - 4 = Specific Unit, 7 = Station
State Unit State as described below
if Unit Number = 1 - 4 then:
0 = Available In
1 = Available Out
2 = Responding
3 = On Scene
4 = Transporting
5 = Facility
6 = Conditional Out of Service
7 = Out of Service
8-15 = Not Used
if Unit Number = 7 then:
0 = Emergency Off, All Station Off
1 = Emergency Off, All Station On
2 = Emergency On, All Station Off
3 = Emergency On, All Station On
4-15 = Not Used
Alert Alert State
if Unit Number = 1 - 4 then:
Zero = Unit Alert Off
Non-Zero = Unit Alert On
if Unit Number = 7 then:
Zero = Station Alert Off
Non-Zero = Station Alert On