Product manual
Data Level Packet Details
71
CAD Command 0: Unit State Control
Byte # 1 2 3 4 5,6 7 8 9 10 11
LABEL STX LL
SEQ#
HL SEQ# Cmd
Num
Station
Address
Unit
Num
State PA
Control
ETX CK
SUM
Range 02 00 or FF 01 to FF
00
0001 to 03FF,
0800
00 to 07 00 to 0F 00 or
NZ
03 xx
Example 02 00 01
00
0004 (10)03 06 00 03 E2
Model 26 Response: Low Level ACK/NAK, Response 3(1), High Level ACK/NAK,
Seq Num High Level Sequence Number, Range 1 - 255
Cmd Num Command Number = 0
Station Address Range: 1 - 1023, & 2048 = All Stations
Unit Num Unit Number, Range: 1 - 4 = Specific unit,
0 = All Units,
7 = Station
State State Control number, depends on unit #:
if Unit Number = 0 - 4 then:
0 = Available In
1 = Available Out
2 = Responding
3 = On Scene
4 = Transporting
5 = Facility
6 = Conditional Out of Service
7 = Out of Service
8-12 = Not Used
13 = No State Change
14 = Alert On
15 = Alert Off
if Unit Number = 7 then:
0-13 = Not Used
14 = Alert On
15 = Alert Off
PA Control: Zero = PA Off, Non-Zero = PA On