Product manual

Introduction
61
CAD Interface Installation
Introduction
This chapter begins with a summary of the connection of a CAD processor to the Model
26 and the programming of the Model 26 to prepare for CAD commands and responses.
The summary is followed by a description of the protocol and the data level which
describes the data content of each packet.
Setup Summary
To set up the connection between the CAD processor and the Model 26:
1. Put the Configuration Switches on the back panel of the Model 26 in the
following positions:
SW-1 ON Address 1 = Master Model 26
SW-2 OFF
SW-3 OFF
SW-4 OFF
SW-5 OFF
SW-6 ON Configuration at 9600 baud
SW-7 ON Configuration program enable
SW-8 OFF
2. Connect a PC or data terminal to the CAD/PRINTER connector with the cable
(part number 709-7208) provided with the equipment (JP-12 should be in the B
position from the factory). If a PC or laptop is being used, make sure the
communication program (HyperTerminal, etc) is set for full duplex (no echo),
9600 baud, 8 bits, no parity, 1 stop bit, and handshake control set to none.