Product manual
Introduction
61
CAD Interface Installation
Introduction
This chapter begins with a summary of the connection of a CAD processor to the Model
26 and the programming of the Model 26 to prepare for CAD commands and responses.
The summary is followed by a description of the protocol and the data level which
describes the data content of each packet.
Setup Summary
♦ To set up the connection between the CAD processor and the Model 26:
1. Put the Configuration Switches on the back panel of the Model 26 in the
following positions:
SW-1 ON Address 1 = Master Model 26
SW-2 OFF
SW-3 OFF
SW-4 OFF
SW-5 OFF
SW-6 ON Configuration at 9600 baud
SW-7 ON Configuration program enable
SW-8 OFF
2. Connect a PC or data terminal to the CAD/PRINTER connector with the cable
(part number 709-7208) provided with the equipment (JP-12 should be in the B
position from the factory). If a PC or laptop is being used, make sure the
communication program (HyperTerminal, etc) is set for full duplex (no echo),
9600 baud, 8 bits, no parity, 1 stop bit, and handshake control set to none.