Product manual

Installation
32 025-9158L
Software Configuration Program
Before the final hardware adjustments can be made, several parameters in the software
that operates the Model 26 must be configured. This is done with the Software
Configuration Program. To access the Software Configuration Program, connect an RS-
232 terminal (or a computer running a terminal emulator program) to the CAD/PRINTER
port on the back panel of the Model 26 using the Zetron programming cable (Zetron Part
No. 709-7211). Make sure JP12 is in position B if using this cable. This cable is shipped
with every Model 26. (See the previous subsection,
CAD/PRINTER Connector, for pin
descriptions). OPTION SWITCH-7 must be in the On position to operate the program.
OPTION SWITCH-6 selects the program’s baud rate, the On position selects 9600 baud,
the preferred speed.
The program operates with the following communication settings:
Baud rate: 9600/1200
(depending on the position of OPTION SWITCH-6)
Start bits: 1
Stop bits: 1
Data bits: 8
Parity: None
To start the Software Configuration Program, press the terminal’s SPACE bar three
times. If everything is connected and configured properly the menu in
Figure 9 will be
displayed on the screen of the terminal.
Figure 9: Model 26 Main Menu