Product manual
Installation
24 025-9158L
Figure 7: Option Switch Address Setting Examples
ON
12345678
ON
12345678
ON
12345678
M26 Address set to 1 = Primary unit
Config Pgm set to 9600 baud (SW6 On)
Serial port set for CAD/Logger (SW7 Off)
M26 Address set to 2 = Secondary unit
Config Pgm set to 1200 baud (SW6 Off)
Serial port set for Config. Pgm. (SW7 On)
M26 Address set to 5 = Secondary unit
Config Pgm set to 9600 baud (SW6 On)
Serial port set for Config. Pgm. (SW7 On)
The Software Configuration Program (see page 32) shares the CAD/PRINTER port with
CAD or data logging. Option Switch 7 selects which function is using this port.
Switch Function
1 This is the least-significant-bit (LSB) of the Model 26’s binary address.
2 This is the second bit of the Model 26’s binary address.
3 This is the third bit of the Model 26’s binary address.
4 This is the most-significant-bit (MSB) of the Model 26’s binary address.
5 Not used
6 Selects the baud rate for the Software Configuration Program as follows:
On position selects 9600 baud
Off position selects 1200 baud
7 Selects/deselects the Software Configuration Program on CAD/PRINTER
port as follows:
On position selects the Software Configuration Program
Off position selects CAD/Data Logging
Note: The Serial Port Configuration setting in the main menu must match
the switch setting for CAD/Data Logging to operate correctly.
8 Not used