Product manual
Setting Voice Audio Output Level to Station PA System
123
Appendix E: Sample Data Log
The following listing is a sample of data log output from the Model 26.
Set Station 1 to alert w/PA from M26
12/22/20 01:23:31 Station - 1 Command : Alert on
Command : PA on
12/22/20 01:23:31 Station - 1 Status : Station alert on
12/22/20 01:23:36 Station - 1 Status : PA on
12/22/20 01:23:46 Station - All Command : PA off
Acknowledge Alert from M6
12/22/20 01:23:56 Station - 1 Status : Station alert off
Set Day/Night Mode to ON from M26
12/22/20 01:24:47 Station - All Command : PA on
12/22/20 01:24:49 Station - 2 Status : PA on
12/22/20 01:24:49 Station - 1 Status : PA on
Set Day/Night Mode to OFF from M26
12/22/20 01:25:40 Station - All Command : PA off
Toggle Sense Input 1 ON and OFF from M6
12/22/20 01:26:59 Station - 1 Sense - 1 Status : Active
12/22/20 01:27:07 Station - 1 Sense - 1 Status : Inactive
Set Station 1 - Unit 1 to alert w/PA from M26
12/22/20 01:29:50 Station - 1 Unit - 1 Command : Alert on
Command : PA on
12/22/20 01:30:00 Station - 1 Unit - 1 Status : Alert on
12/22/20 01:30:05 Station - 1 Status : PA on
12/22/20 01:30:14 Station - All Command : PA off
Change Status of Station1-Unit1 to "Responding" from M26 (Alert still active)
12/22/20 01:31:10 Station - 1 Unit - 1 Status : Alert off
Status : Responding
Change Status of Station1-Unit1 back to "In Quarters" from M6
12/22/20 01:32:07 Station - 1 Unit - 1 Status : In Quarters
Power down Station 1 Transponder
12/22/20 01:33:50 Station - 1 Status : Off Line
Power up Station 1 Transponder
12/22/20 01:35:21 Station - 1 Status : On Line