Product manual

Model 26 Conventional - Dedicated Radio / Series 4000 Console
107
Model 26 Conventional - Dedicated Radio / Series 4000 Console
Zetron Model 4010, Model 4024 or Model 4048 Channel Card Option Switch settings:
Set Busy Transmit Inhibit switch ON for applicable channel.
Set Cross Mute Enable switch (OPT) ON for applicable channel.
Model 26 programming:
Set Data Mute Active Polarity - LOW
Set PA Ready Active Polarity - HIGH
Set Communications mode to COR, TX on COR HI/LOW if COR signal is
available.
Set Communications mode to VOX if COR signal not available.
Set FFSK Mute Debounce no more than 0.25 seconds.
Use PA Ready to allow the console to send audio to the Model 6s.