Instruction manual
Adjustment Procedures
025-9416 87
D i s p l a y R e c o r d
ServiceName: test_v
Priority: B
PromptName: standard
DeliveryName: standard
PagerDefinition: 2tone
VoiceLimit: 131
DisplayLimit: 0
EmptyMsg: Y
Talkback: N
(<cr>, P, D, M, N, L, F, T, B, ?, .)
Entry:
Choose any logical
name that describes
the class.
Breakthrough
priority sends the
page out “live” over
the air.
Give the entry the
maximum voice
limit.
Figure 49. Model 640 Database 2-Tone Class of Service Record
q
4. Save the record by entering S.
q
5. Create a new Subscribers record as follows:
• Enter a period (.) to back out to the Subscriber Phone Numbers menu.
• Select 1 - Subscribers.
• Enter N to create a New record.
• Fill in the record as shown in Figure 50.
D i s p l a y R e c o r d
PhoneNumber: 999
SubscriberName: test01
ServiceName: test_v
Capcode: C247
SecurityCode :
Status: V
CallCount: 0
(<cr>, P, D, M, N, L, F, Z, S, T, B, ?, .)
Entry:
Any unused
phone number
Corresponds to
class of service
created in step #3
Must be valid
record for testing
Figure 50. Model 640 Database 2-Tone Subscribers Record
q
6. Save the record by entering S.
q
7. Connect the voltmeter to the appropriate pins that extend off the sides of the potentio-
meters. Use the top and bottom pins to adjust trunk A/C. Use the middle and bottom
pins to adjust trunk B/D. Refer to Figure 51.