Instruction manual

Communications Setup
025-9416 39
enter “1-aaa-xxx-xxxx,,,,,0555”.
1-aaa-xxx-xxxx = paging terminal phone number; 1 + area code (aaa)
,,,,, = pauses to allow the paging terminal to prepare for overdialing
0555 = default ConsoleNumber
q
8. Alternately, if the ZLINK connection is local (computer or dumb terminal), indicate
the appropriate baud rate for serial communications and identify the connection is
local as “B#L”.
B = indicates the baud rate is to follow
# = the communications speed (any rate between 512 and 9600)
L = local connection
Example: For 4800 baud local communication enter “B4800L”.
q
9. Enter the Password for ZLINK access to the paging terminal. The password is a text
string, up to 9 characters in length. Spaces are allowed and the password is case-
sensitive.
I CAUTION
Write the password down in a safe place, in case it is forgotten. Do NOT
give the password to unauthorized personnel.
q
10. Enter the number of the computer’s Comm Port used to connect to the Model 640. 1-
4 are the allowed entries. If the communication port is a non-standard type, identify
the port as follows:
pBASEaaaIRQx
p = port # (5 -9 allowed)
aaa = base I/O address of the port
x = IRQ address to use (2 - 7 allowed, usually 3 or 4)
q
11. Once all the fields in the Comm window are properly entered, save the record and
exit to the MCU main menu by pressing <Esc>.
Note: If a remote connection (modem) to the paging terminal will be used, it is
recommended that a temporary local connection (usually with a laptop computer) be
made for installation diagnostics. Refer to “Local Serial Connection” on page 34 for
details.
q
12. Power up the Model 640 and let it complete its boot sequence (all lights have
extinguished except the READY light is on solid).
q
13. Select Comm, Zlink from the main menu. MCU attempts to make a connection with
the Model 640.