Instruction manual

Optional Equipment Installation
106 025-9416
SecondZone:
(none — just press spacebar)
SecondRepeat: 0
SecondDelay: 0
ThirdZone:
(none — just press spacebar)
ThirdRepeat: 0
ThirdDelay: 0
ForthZone:
(none — just press spacebar)
ForthRepeat: 0
ForthDelay: 0
e. Enter S (for Save).
f. Repeat steps c-e for all 8-character names from Table 1.
2. Set up the Class of Service database.
a. From the Model 640 Databases menu select 1 - Subscriber Phone Numbers.
b. From the Subscriber Phone Numbers menu select 2 – Class of Service.
c. At the Entry prompt enter N (for New).
d. Enter the following information.
ServiceName
(arbitrary)
Priority L
PromptName Standard
DeliveryName
8-character name from Table 1
PagerDefinition (Pocsag, Golay, or New Flex)
VoiceLimit 00
DiplayLimit
(any limit up to 500 characters)
EmptyMsg N
TalkBack N
e. Enter S (for Save).
f. Repeat steps c-e for all 8-character names from Table 1.
3. Program subscribers.
a. From the Model 640 Databases menu select 1 - Subscriber Phone Numbers.
b. From the Subscriber Phone Numbers menu select 1 – Subscriber.
c. At the Entry prompt enter N (for New).
d. Enter the following information.
PhoneNumber
(7-digit ID number)
SubscriberName
(last 7 digits of ID # on remote system)
ServiceName
(ServiceName from step 2)
Capcode
(Pager-specific; enter a dummy capcode if no local page needed)
SecurityCode
(only if needed)