Instruction manual

Optional Equipment Installation
104 025-9416
In Table 4 the 5
th
byte of each line of OparamData is 00. That corresponds to the TAP
number, so increment it also.
7. Enter the RawNames and OparamData listed in Table 7 to initialize the external modem.
Table 7:
MDM-1 10 00 14 F8 41 54 26 46 26 4D 30 26 4B 30 26 48 30 26 42 31 58 33 0D
MDM-2 10 00 06 F6 41 54 42 31 0D
M640 System Programming
This section requires you to connect with the system, upload the new software, retrieve current
configuration files, edit them with a text editor, and return the edited files to the system.
Note: If you need assistance with this please call M640 technical engineering at 1-425-820-6363
and an M640 technical engineer will assist you. Please have your Z-number and Table 1
completed and ready to fax before you call.
1. Save the new image file (that was sent to you on a floppy disk or e-mailed to you) to the
C:\MCU folder.
2. From the main menu in MCU, select COMM then ZLINK. This should connect with the
M640 and display a + prompt.
3. At the + prompt enter:
dos copy c:\mcu\filename.img
where filename.img is the name of the image file. The message “1 file copied
should appear when the copy is completed.
4. At the + prompt enter:
put filename.img
The message “Put complete” should appear when the transfer is completed. This may take
a few minutes if connected by way of modem.
5. Modify configuration file Config.cds.
CAUTION: Incorrect configuration of this file could disable your system.
a. At the + prompt enter:
get config.cds
The message “Get complete” should appear when the transfer is completed.
b. At the + prompt enter:
dos edit config.cds
c. Find the line that reads:
16 8 a:\zdir\oldfilename.img
where oldfilename.img is the name of your old image file.
d. If there is a semi-colon at the beginning of this line, delete it.
e. Edit the line so that it reads as follows: