Instruction manual
Optional Equipment Installation
025-9416 103
DTMF Digit
Decimal Value
ASCII Value
6 36
7 37
8 38
9 39
Note 3: Replace 0X with the hexadecimal value for the total number of bytes
following it, including the 00 at the end of the string, per Table 6. For example,
for the entry shown in Table 4 it would be 15 decimal, which converts to 0F hex.
Table 6:
Decimal Hex Decimal Hex
0 00 16 10
1 01 17 11
2 02 18 12
3 03 19 13
4 04 20 14
5 05 21 15
6 06 22 16
7 07 23 17
8 08 24 18
9 09 25 19
10 0A 26 1A
11 0B 27 1B
12 0C 28 1C
13 0D 29 1D
14 0E 30 1E
15 0F 31 1F
Note 4: If remote provider requires 10-digit Ids, replace aa aa aa with the ASCII values
for the area code to be prefixed to the ID number sent to the remote provider, per Table 5.
g. At the Entry prompt enter L (for List all raw oparams).
h. When prompted to send the information to the printer, type N for No.
i. Verify all RawNames and OparamData. If you need to change any of them, press Enter to
get to the RawName that you want to change, then enter M (for Modify), then repeat the
steps as necessary.
6. Go back to step 5 and repeat the data entry process for the rest of the internal destinations
from Table 1, but make the following changes:
• Increment the RawNames for each successive TAP destination. That is, instead of entering
00baud, 00session, etc., as you did for TAP00, enter 01baud, 01session, etc., for
TAP01; 02baud, 02session, etc., for TAP02; and so on.