Instruction manual
Optional Equipment Installation
98 025-9416
TNPP INTERFACE
Several networking options include the TNPP interface (Part No. 702-9362) card. The following
figure gives an overview of M640 TNPP capcode paging flow:
Installation Procedure
q
1. Power-down the paging terminal.
q
2. Remove the top cover.
q
3. Plug the TNPP card into connector J8, located in the middle, rear of the chassis.
Refer to Section 3 for illustrations of the Model 640 and the correct location of each
interface card.
q
4. Secure the card guide to the top of the back panel with the provided screw.
q
5. Power-up the unit and let it complete its boot sequence (all lights have extinguished,
except the READY LED is on solid).
q
6. The Model 640 software requires several changes to implement the TNPP card. Refer
to the Model 640 Operating and Programming Manual (Part No. 025-9417) for
details on how to edit the databases and system files.
q
7. After the paging terminal has been configured, reboot the Model 640 to initialize the
TNPP option.