Instruction manual
Adjustment Procedures
025-9416 91
Entry: n
PagerDefinition: 2t=vtest
SecondsTone1: 12
SecondsGap: 00.00
SecondsTone2: 12
(A, R, S,?)
Entry:
Choose any logical
name that describes
the pager type.
Enter the
maximum tone
length.
Figure 52. Model 640 Database 2-Tone Pager Definitions Record
q
2. Save the record by entering S.
q 3. Create a new Class of Service in the Model 640 database as follows:
• Enter a period (.) to back out to the Subscriber Phone Numbers menu.
• Select 2 - Class of Service.
• Enter N to create a New record.
• Fill in the record as shown in Figure 53.
D i s p l a y R e c o r d
ServiceName: 2ttest
Priority: B
PromptName: standard
DeliveryName: standard
PagerDefinition: 2t+vtest
VoiceLimit: 60
DisplayLimit: 25
EmptyMsg: Y
Talkback: N
(<cr>, P, D, M, N, L, F, T, B, ?, .)
Entry:
Choose any logical
name that describes
the class.
Breakthrough
priority sends the
page out “live” over
the air.
Give the entry the
adequate voice and
display limits.
Coresponds to the
pager definition
created in step #1.
Figure 53. Model 640 Database 2-Tone Class of Service Record
q
4. Save the record by entering S.
q
5. Create a new Subscriber in the Model 640 database as follows:
• Enter a period (.) to back out to the Subscriber Phone Numbers menu.
• Select 1 - Subscribers.
• Enter N to create a New record.
• Fill in the record as shown in Figure 54.