Instruction manual
Programming
Frog 2 Operating Manual – Issue 4.3 Page 93
Fade Time Commands – Program Window
The following commands can be used to set the fade times for the selected fixtures
in the
Program Window:
TIME X ENTER
Sets the fade times for all fixture parameters to X
seconds
TIME U/D ENTER
Sets the intensity fade up and fade down times to U and
D seconds respectively.
TIME COLOUR X ENTER
Sets the fade times for all colour parameters to X
seconds
TIME BEAM X ENTER
Sets the fade times for all beamshape parameters to X
seconds
TIME POSITION X ENTER
Sets the fade times for all position parameters to X
seconds.
TIME U/D COLOUR X BEAM Y
POSITION Z ENTER
Sets the intensity fade up and fade down times to U and
D, the colour fade times to X, the beamshape fade times
to Y and the position fade times to Z.
Fade Time Commands – Recording Cues
When recording a cue - fade times can be specified in the command syntax for all fixture
parameters, individual attributes or combinations of attributes as follows:
RECORD (CUE) S/C TIME X ENTER
Sets the fade times for all fixture parameters to X
seconds.
RECORD (CUE) S/C TIME U/D
ENTER
Sets the intensity fade up and fade down times to U and
D seconds respectively.
RECORD (CUE) S/C TIME COLOUR X
ENTER
Sets the fade times for all colour parameters to X
seconds.
RECORD (CUE) S/C TIME BEAM X
ENTER
Sets the fade times for all beamshape parameters to X
seconds.
RECORD (CUE) S/C TIME POSITION
X ENTER
Sets the fade times for all position parameters to X
seconds.
RECORD (CUE) S/C TIME U/D
COLOUR X BEAM Y POSITION Z
ENTER
Sets the intensity fade up and fade down times to U and
D, the colour fade times to X, the beamshape fade times
to Y and the position fade times to Z.