Instruction manual

Cues, Stacks and Pages
Page 122 Frog 2 Operating Manual – Issue 4.3
Move on Dark Options
Select the [Move on Dark] button in the Cue Stack Setup Window.
The various options are described below:
Move on Dark - Enabled or Disabled (default = Disabled)
When this function is enabled for the cue stack whenever a fixture goes black (ie it’s
intensity falls to zero, or the shutter is closed), the desk software will look ahead in the
cue stack to see what values the colour, beamshape and position parameters are next
programmed at for that fixture.
It will then output those values shortly after the fixture has gone black (according to the
delay and fade times set in the window). When the fixture comes back on again in a
later cue, the colour, gobo, position etc. will already be at their correct values and just
the intensity will fade up or the shutter open.
Delay Time – Range 0 – 99:59.9 (default = 3 seconds)
Fade Time – Range 0 – 99:59.9 (default = 1 second)