Instruction manual
Cues, Stacks and Pages
Page 118 Frog 2 Operating Manual – Issue 4.3
Master Fader
The operation of the MASTER fader for a cue stack is defined in the Cue Stack Setup
Window and may be one of the following options:
• HTP Master – Simply controls the maximum level of the programmed HTP channels.
Cues are triggered via the GO key. This is the default option.
• Manual Fader (2 Way) – Press the GO button to activate the playback. The next cue in
the cue stack is automatically loaded when the fader reaches either end
of it’s travel
(0% or 100%). Moving the fader creates a dipless cross-fade between the two cues.
The fader controls the HTP levels; the LTP channels are triggered when the fader is
moved from the end stop and then fade according to the times in the incoming cue.
• Manual Fader (1 Way) - Press the GO button to activate the playback. The next cue in
the cue stack is automatically loaded when the fader reaches zero. The fader controls
the HTP levels; the LTP channels are triggered when the fader is moved from zero and
then fade according to the times defined in the incoming cue.