Instruction manual
Setup
Page 62 Leap Frog 48/96 Operating Manual – Issue 3
Behaviour
Press the [Behaviour] MFK or select the [Behaviour] button on the monitor. The various
options are shown on the MFKs and monitor and are summarised below:
• Confirm Overwrites – When this option is set to Yes a confirmation window will
appear on the monitor screen when overwriting a memory, submaster, palette, effect,
macro etc.
• Recovery Mode – When the desk loses power and then has power restored, should
the desk recover to the last outputting memory/submaster, or go to a blackout.
• Keep Parameters Separate
The Keep xxx Parameters Separate options are only applicable in Basic Partial mode.
If the options are set to ‘Yes’ then each individual parameter in that attribute will be
tagged separately (eg in a CMY fixture, if Cyan is adjusted, only Cyan will be tagged). If
the attribute is set to ‘No’ then as soon as one parameter in that attribute is adjusted, all
the parameters in that attribute will be tagged automatically (eg in a CMY fixture, if
Cyan is adjusted, then Cyan, Magenta, Yellow and any other colour parameter for the
fixture will be tagged automatically).
• Preset Mixing – HTP = Highest Takes Precedence (in two preset mode, if Preset A
level is 40% and preset B level is 60%, the output level is 60%).
LTP = Latest Takes Precedence. Use the preset fader to match the current output level
for the dimmer. Once the level has been picked up, you can adjust the level up or down
using the fader. Note that when the Preset Mixing is set to HTP mode, the preset
faders are NOT shown in the Program Window.