Instruction manual

Setup
Page 60 Leap Frog 48/96 Operating Manual – Issue 3
Inputs
Press the [Inputs] MFK or select the [Inputs] button on the monitor. The various options
are shown on the MFKs and monitor and are summarised below:
SMPTE Timecode – Disabled or 24, 25, 30 Frames per Second.
MIDI Timecode – Disabled or 24, 25, 30 Frames per Second.
CAN – Disabled, iCAN or Chillinet.
MIDI Notes Disabled, Channels, Submasters or Memories.
Remote Switches Each of the six remote switches can be configured as Disabled,
GO, Go to Memory or Macro. If the action field is set to Go to Memory or Macro, then
an additional field is displayed allowing you to enter the memory or macro number.
Note – SMPTE, MIDI, CAN and Remote Switches
These input functions are only applicable if the optional upgrade card has been fitted to the
Leap Frog 48/96 desk.
Note –Remote Switches, Go to Memory and Macros
If a remote switch is configured to be a Go to Memory or Macro and the memory or macro
is subsequently deleted, the action of the remote switch is changed to Disabled.