FRAMING CONSTRUCTION EXTERIOR ROOF OR CHASE
WARNING: Install the hearth protector or finished hearth extension only as specified. The exten-
sion must extend a minimum of 16" in front of the stove door opening and must be 47 1/2" wide mini-
mum. Refer to (Page 6) for calculation of R, and K values. (See Page 19).
NOTE: No floor protector or finished hearth is needed directly under the Model 80ZC Cabinet, only the
hearth protector is needed.
CONTINUED FRAMING AND INSTALLATION
2. The 80ZC cabinet exterior roof or chase framing as follows:
CHIMNEY
STORM COLLAR
ROOF FLASHING
CHIMNEY PIPE
USE FIRE CODE SHEET ROCK
2" X 4" STUDDING
DOUBLE HEADER: A DOUBLE HEADER
MUST BE USED ON A LOAD BEARING WALL.
THIS MUST BE DONE 12"
ABOVE CABINET.
SINGLE HEADER: A SINGLE HEADER MUST BE
USED AS PAT OF FRONT FRAMING. VERTICAL
2" X 4"‘s MUST BE TURNED FLAT.
47 1/2"
41 1/2"
FIGURE 18