ZERIO PLUS EDA-Z5008, Z5020 & Z5100 USER MANUAL ZPControlUserMan_r100 Revision 1.
EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 0359 Electro Detectors Limited Electro House Edinburgh Way Harlow, Essex CM20 2EG, UK 14 0359 CPR 00226 DOP_EDA_Z5100 (covers all models) EN54-2:1997+A1:2006 EN54-4:1997+A1:2002+A2:2006 EN54-25:2008 Control and indicating equipment for fire detection and fire alarm systems for buildings Models: EDA-Z5008, EDA-Z5020, EDA-Z5100 Optional functions w
EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ Revision History V1.00 19/01/2015 User manual first release.
EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ Introduction Electro Detectors has been manufacturing radio fire alarm systems since 1987 and with the introduction of a harmonised specification for Europe has complemented its range of products to meet EN54 Part 25. Based on the popular Zerio system, the updated Zerio Plus has been designed to be capable of handling 240 devices in 100 zones.
EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ Contents 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 Front Panel Layout User Operation 2.1 System Normal 2.2 Fault Conditions 2.3 Silence Buzzer 2.4 Reset a Fault 2.5 Alarm Conditions 2.6 Silence the Alarm 2.7 Re-sound the Sounders 2.8 Reset the Alarm 2.9 Access Levels Menu Operation 3.1 Quick Menu Setup Menu 4.
EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 1.0 - Front Panel Layout ① ② ③ ⑤ ④ ⑥ ① Fire LEDs If the panel goes into alarm, these LEDs will flash until the panel is reset. ② Zone Alarm LEDs In a fire condition, the appropriate zone LED will illuminate. If the fire condition exists across multiple zones, multiple zone LEDs will be illuminated.
EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ ④ Fault LEDs Common Fault Device or panel has a fault. See main display for details. This LED will remain lit until the panel has been reset. System Fault Fault that affects system performance. See main display for details. Sounder Flt/Disable If the LED is flashing, there is a fault with one or more sounders.
EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 2.0 - User Operation 2.1 - System Normal In normal operation the screen will show either the date and time, or the supplier/service contact details. The unit can also be configured to alternate between the two. If configured this way, the display will change every 4 seconds. Also a single green ‘Supply’ LED will be illuminated.
EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 2.6 - Silence the Alarm When it is certain that it is safe to return to the building the Silence Alarm button should be pressed. The user will then be prompted to enter a valid user access code using the navigation keys. Up to 30 seconds should then be allowed for all sounders to silence.
EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 3.0 - Menu Operation To enter the menu system, press Menu. This will display an overview of any alarms, faults, disablements or tests that are currently active, along with an option to access the Main Menu. The options available on the main menu and sub-menus will be dependent on the access code entered and its corresponding access level.
EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 4.0 - Setup Menu 4.1 - Changing the system Time and Date – all access levels 1.Main Menu>>1.Setup>>1.Time & Date To change the time and date settings use the ← and → keys to navigate to the value, and the ↑ or ↓ keys to select the desired value. Press Enter to accept or Cancel to exit.
EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ Disable Panel Inputs – all access levels 1.Main Menu>>2.Disable/Enable>>1.Disable>>3.Panel Input The two monitored inputs can each be disabled for a period of time specified by the user, dependent on their access level. All access levels can disable an input for a period of 1 to 96 hours.
EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ Enable a Zone – all access levels 1.Main Menu>>2.Disable/Enable>>2.Enable>>1.Zone To enable a previously disabled zone, select it using the ↑ or ↓ keys and press Enter. To enable more zones press Enter, or Cancel to exit. If all zones have been enabled ‘No Zones to enable’ will be displayed.
EDA-Z5008, Z5020 & Z5100 – User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 6.0 - Test Mode Test mode allows a system to be tested with minimal disruption to the occupants of a building. When a zone is placed into test mode the engineer can choose to disable sounders, actuators or any output devices. Should anything happen outside of these selected zones the system will operate as normal and the sounders will sound.
EDA-Z5008, Z5020 & Z5100 –User Manual ZPControlUserMan_r100 _____________________________________________________________________________________________________ 6.3 - Lamp/Buzzer Test – advanced, service and commissioning users 1.Main Menu>>3.Test Mode>>3.Lamp/Buzzer Test This option will illuminate all the panels LEDs in sequence, to check they are working properly. The panel buzzer will also sound. A quick lamp test can be performed from any screen by holding down the Menu button for 2 seconds. 7.
Zerio Plus Hardware Product EDA-A6000 EDA-A6030 EDA-A6060 EDA-C5000 EDA-D5000 EDA-D6000 EDA-D6030 EDA-R5000 EDA-R6000 EDA-R6030 EDA-T5000 EDA-T5100 EDA-T6080 Description Radio Sounder Radio Sounder with LED Beacon Radio LED Beacon Radio Callpoint/Break Glass Unit Radio Heat Detector Radio Heat Detector with Combined Sounder Radio Heat Sounder Detector with LED Beacon Radio Optical Smoke Detector Radio Optical Smoke Detector with Combined Sounder Radio Optical Smoke Sounder Detector with LED Beacon Radio Tr