Use, Care, and Installation Guide www.zephyronline.com Siena Pro ZSP-E36BS ZSP-E42BS ZSP-E48BS Model number: Serial Number: SEP20.0501 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet........................................ Mounting Height & Clearance................................. Ducting Options............................................................ Hood Specifications.................................................... Mounting the Range Hood....................................... 5 6 7 8 9 FEATURES & CONTROLS ICON Touch Controls................................................. 10 MAINTENANCE Cleaning, Filter Care, Part List............
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
List of Materials www.zephyronline.
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight Equivalent number length x used = Total 3-1/ 4” x 10” 5 Ft. Rect. to 6” round transition x( ) = Ft. 3-1/ 4” x 10” 20 Ft. Rect. to 6” round transition 90 0 elbow x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. Ft. x( ) = Ft. 24 Ft. x( ) = Ft.
Installation – Mounting Height & Clearance www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 10” to 12”. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible. A n. mi . B x a m C n. mi . D x a m Minimum mount height between range top to hood bottom should be no less than 24”. in. ” max. 4 2 ”m 34 Maximum mount height should be no higher than 34”.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
3” 16 11/16” 11 5/16” 1 9/16” 35 7/8”, 41 7/8”, 47 7/8” FRONT 12 3/16” STANDARD min. ducted - 27 1/2” min. recirc. - N/A max. - 42” Z1C-00SP min. ducted - 45” min. recirc. - N/A max. - 78” 21 15/16” SIDE 6 3/4” 6 9/16” AC In 1” Installation – Hood Specifications www.zephyronline.
Installation – Mounting the Hood ! CAUTION: At least two installers are required due to the weight and size of the hood. C/L 1. Measure from range top to hood bottom and mark line A. (24” minimum from range top). Duct Cover Bracket 2. Plum and mark center line. 3. Mark mounting height line B. (12-1/8” from line A) 4. Mark mounting spread from C/L on line B 14-15/16” 14-15/16" B 5. Fasten (2) 4 x 38 screws into studs on line B. Do not fasten screws all the way.
Features & Controls - ICON Touch Controls www.zephyronline.com Power / Delay Off Adjust 5 Speed Levels Lights Low/High/Off Display (speed level, delay off, filter clean/change) 1 POWER / DELAY OFF BUTTON Power Button Function - Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights.
Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain. Do not use any product containing chlorine bleach.
Maintenance – Lights www.zephyronline.com LED LIGHT STRIPS In the unlikely event that your LED strip fails, please contact Zephyr to order replacement parts. See list of parts and accessories page for part #’s and contact information. To replace LED light strip 1. Remove aluminum mesh filters. 2. Remove light panel by two screws. 3. Disconnect LED light strip quick connector. 4. Push in the two side clips on the ends of the LED strip. 5. Push LED light strip through the light panel opening.
Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels; 590 or 390 CFM. The usage of ACT may not be necessary for your installation. Please check your local codes for CFM restrictions.
Blower Fan Curve Model: ZSP AC Input: 120V, 60Hz Outlet Diameter: 10in Pressure (inAq) Fan Curve Diagrams www.zephyronline.com 2.80 2.70 2.60 2.50 2.40 2.30 2.20 2.10 2.00 1.90 1.80 1.70 1.60 1.50 1.40 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.
15 Fan Curve Diagrams
Wiring Diagrams www.zephyronline.
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The wires on the control board are loose. 3. Make sure the wires on the control board are connected properly. 4. The switch board and control board wirings are disconnected. 4.
Warranty www.zephyronline.
PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
Guide d’utilisation, d’entretien et d’installation www.zephyronline.com Siena Pro ZSP-E36BS ZSP-E42BS ZSP-E48BS Model number: Serial Number: SEP20.0501 © Zephyr Ventilation LLC.
www.zephyronline.
2-3 LISTE DU MATÉRIEL....................................................................................................................... 4 INSTALLATION Feuille de calcul pour le conduit............................................................................... Espace libre et hauteur de montage........................................................................... Options d’installation pour le conduit...................................................................................
www.zephyronline.com Mise en garde de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, communiquez avec le fabricant. b.
POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage. FONCTIONNEMENT Laissez toujours les grilles de sûreté et les filtres en place.
Liste du matériel www.zephyronline.
= Longueur x Nombre utilisé Pièces de conduit Total 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit x( ) = pi x( ) = pi x( ) = pi x( ) = pi x( ) = pi 23 pi 7” circ. à rect. de 3-1/4" x 10", coude à 90º x( ) = pi 3-1/ 4” x 10” 30 pi embout mural rect.
Installation – Espace libre et hauteur de montage www.zephyronline.com Lorsqu’il possible de le faire, diminuez TOUJOURS le nombre de pièces et de changements de direction. Si un long tronçon de conduit est nécessaire, augmentez le diamètre du conduit de 10” à 12”. Si des changements de direction ou des adaptateurs sont nécessaires, installez-les le plus loin possible de l’ouverture et le plus éloigné possible l’un de l’autre. n. A mi . B x a m n. C mi .
N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de recirculation d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple. Fixez toutes les pièces du conduit avec des vis à tôle et isolez tous les joints avec du ruban adhésif en toile ou du ruban réflecteur certifié.
3” 16 11/16” 11 5/16” 1 9/16” 35 7/8”, 41 7/8”, 47 7/8” Devant de la hotte 12 3/16” STANDARD min. ducted - 27 1/2” min. recirc. - N/A max. - 42” Z1C-00SP min. ducted - 45 min. recirc. - N/A max. - 78” 21 15/16” Côté de la hotte Entrée élec. 6 3/4” 6 9/16” 1” Installation – Spécifications de la hotte www.zephyronline.
1. Prenez la mesure entre la surface de la cuisinière et la base de la hotte; marquez la ligne A (min. 24” à partir du dessus de la cuisinière). Installation – Montage de la hotte ! ATTENTION : Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. L/C Support pour le recouvrement du conduit 2. Marquez la ligne centrale avec exactitude. 3. Marquez la ligne de hauteur de montage B (à 12-1/8” de la ligne A). 4.
Commandes - ICON Commandes à effleurement www.zephyronline.com Mise en marche/Arrêt à retardement Choix de 5 vitesses Lumières: faible / élevée / éteinte Afficheur (vitesse, arrêt à retardement, nettoyage/changement des filtres) 1 MISE EN MARCHE/ARRÊT À RETARDEMENT Fonction de la touche de mise en marche - La touche permet d’allumer et d’éteindre toutes les fonctions de la hotte (ventilateurs et lumières). - La hotte se rappelle la dernière vitesse et le dernier niveau d’éclairage utilisés.
Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. Pour les taches plus tenaces, utilisez du produit dégraissant liquide. Après le nettoyage, vous pouvez polir les surfaces avec des produits de polissage à acier inoxydable non abrasifs pour redonner de l’éclat et du lustre aux surfaces.
Maintenance - Lumières www.zephyronline.com Bandes de lumière LED Dans l’éventualité peu probable d’une défaillance de votre bande de LED, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la liste des pièces et accessoires à la page pour les références et les coordonnées. Pour remplacer la bande lumineuse à LED 1. Retirez les filtres à mailles en aluminium. 2. Retirez le panneau d’éclairage à l’aide de deux vis. 3. Débranchez le connecteur rapide du bandeau lumineux à LED. 4.
Certains codes et règlements limitent la quantité maximale de pi3/min qu’une hotte peut extraire. La ACT permet de contrôler la quantité maximale de pi3/min qu’évacuent un éventail de hottes Zephyr, éliminant la nécessité d’acheter un dispositif d’air d’appoint dispendieux. La ACT permet à l’installateur d’ajuster facilement la vitesse maximale du ventilateur à l’un des niveaux de pi3/min les plus fréquemment utilisés : 590 pi3/min ou 390 pi3/min.
Diagrammes des courbes caractéristiques des ventilateurs www.zephyronline.
15 Diagrammes des courbes caractéristiques des ventilateurs
Schema De Circuits www.zephyronline.
Problème Cause Solution Après l’installation, l’appareil ne fonctionne pas. 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur et de l’appareil est allumée 2. La ligne électrique et le raccord de câble ne sont pas correctement branchés 2. Vérifiez que le branchement de l’appareil a été fait correctement Les lumières fonctionnent, mais le ventilateur ne tourne pas. L’appareil vibre. L’appareil émet un sifflement. 3.
Garantie www.zephyronline.
ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire. Il vous permet de recevoir des avis concernant des modifications ou des rappels de produits.