Use, Care, and Installation Guide www.zephyronline.com Siena Pro ZSP-E36BS ZSP-E42BS ZSP-E48BS Model number: Serial Number: APR19.0301 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... +RRG 6SHFL¿FDWLRQV ................................................... Mounting the Range Hood ...................................... 5 6 7 8 9 FEATURES & CONTROLS ICON Touch Controls ................................................ 10 MAINTENANCE Cleaning, Filter Care, Part List .............
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages. OPERATION $OZD\V OHDYH VDIHW\ JULOOHV DQG ¿OWHUV LQ SODFH :LWKRXW WKHVH FRPSRQHQWV RSHUDWLQJ EORZHUV FRXOG FDWFK RQWR KDLU ¿QJHUV and loose clothing.
List of Materials www.zephyronline.
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight Equivalent number length x used = Total 3-1/ 4” x 10” 5 Ft. Rect. to 6” round transition x( ) = Ft. 3-1/ 4” x 10” 20 Ft. Rect. to 6” round transition 90 0 elbow x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. Ft. x( ) = Ft. 24 Ft. x( ) = Ft.
Installation – Mounting Height & Clearance www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 10” to 12”. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible. A n. mi . B x a m C n. mi . D x a m Minimum mount height between range top to hood bottom should be no less than 24”. in. ” max. 4 2 ”m 34 Maximum mount height should be no higher than 34”.
1(9(5 H[KDXVW DLU RU WHUPLQDWH GXFW ZRUN LQWR VSDFHV EHWZHHQ ZDOOV FUDZO VSDFHV FHLOLQJ DWWLFV RU JDUDJHV All exhaust must be ducted to the outside, unless using the recirculating option. 8VH VLQJOH ZDOO ULJLG 0HWDO GXFWZRUN RQO\ )DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL¿HG 6LOYHU 7DSH RU 'XFW 7DSH Some Ducting Options Roof Pitch w/ Flashing & Cap side wall cap w/ gravity damper Soffit or crawl space side wall cap w/ gravity damper 7 Installation – Ducting Opti
3” 16 11/16” 11 5/16” 1 9/16” 35 7/8”, 41 7/8”, 47 7/8” FRONT 12 3/16” STANDARD min. ducted - 27 1/2” min. recirc. - N/A max. - 42” Z1C-00SP min. ducted - 45” min. recirc. - N/A max. - 78” 21 15/16” SIDE 6 3/4” 6 9/16” AC In 1” Installation – +RRG 6SHFL¿FDWLRQV www.zephyronline.
0HDVXUH IURP UDQJH WRS WR KRRG ERWWRP DQG PDUN OLQH $ ´ PLQLPXP IURP UDQJH WRS C/L 3OXP DQG PDUN FHQWHU OLQH Duct Cover Bracket 0DUN PRXQWLQJ KHLJKW OLQH % ´ IURP OLQH $ 0DUN PRXQWLQJ VSUHDG IURP & / RQ OLQH % ´ 14-15/16" )DVWHQ [ VFUHZV LQWR VWXGV RQ OLQH % 'R QRW IDVWHQ screws all the way. Note: wood blocking may need to 1-3/8" be added behind the drywall if no studs are present.
Features & Controls - ICON Touch Controls www.zephyronline.com Power / Delay Off Adjust 5 Speed Levels Lights On/Dim/Off Display (speed level, delay off, filter clean/change) 1 POWER / DELAY OFF BUTTON Power Button Function - Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights.
Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and EXႇ RXW WKH VWDLQOHVV OXVWHU DQG JUDLQ $OZD\V VFUXE OLJKWO\ ZLWK FOHDQ FRWWRQ FORWK DQG ZLWK WKH JUDLQ Do not use any product containing chlorine bleach.
Maintenance – Lights www.zephyronline.com LED LIGHT STRIPS ,Q WKH XQOLNHO\ HYHQW WKDW \RXU /(' VWULS IDLOV SOHDVH FRQWDFW =HSK\U WR RUGHU UHSODFHPHQW SDUWV 6HH OLVW RI SDUWV DQG DFFHVVRULHV SDJH IRU SDUW ¶V DQG FRQWDFW LQIRUPDWLRQ To replace LED light strip 5HPRYH DOXPLQXP PHVK ¿OWHUV 2. Remove light panel by two screws. 'LVFRQQHFW /(' OLJKW VWULS TXLFN FRQQHFWRU 4. Push in the two side clips on the ends of the LED strip. 5. Push LED light strip through the light panel opening.
ACT Conversion ALUÀRZ &RQWURO 7HFKQRORJ\ $&7 Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the PD[LPXP EORZHU &)0 RI VHOHFW =HSK\U 9HQWLODWLRQ UDQJH KRRGV ZLWKRXW WKH QHHG IRU H[SHQVLYH PDNH XS DLU NLWV $&7 HQDEOHV WKH LQVWDOOHU WR HDVLO\ VHW WKH PD[LPXP EORZHU VSHHG WR RQH RI WZR PRVW FRPPRQO\ VSHFL¿HG &)0 OHYHOV RU &)0 7KH XVDJH RI $&7 PD\ QRW EH QHFHVVDU\ IRU \RXU LQVWDOODWLRQ 3OHDVH FKHFN \RXU ORFDO codes for CFM restrictions.
Blower Fan Curve Model: ZSP AC Input: 120V, 60Hz Outlet Diameter: 10in Pressure (inAq) Fan Curve Diagrams www.zephyronline.com 2.80 2.70 2.60 2.50 2.40 2.30 2.20 2.10 2.00 1.90 1.80 1.70 1.60 1.50 1.40 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.
15 Fan Curve Diagrams
Wiring Diagrams www.zephyronline.
Issue Cause What to do After installation, the unit doesn’t ZRUN 1. The power source is not turned ON. 0DNH VXUH WKH FLUFXLW EUHDNHU DQG WKH XQLW¶V power is ON. 7KH SRZHU OLQH DQG WKH FDEOH ORFNLQJ FRQQHFWRU is not connecting properly. &KHFN WKH SRZHU FRQQHFWLRQ ZLWK WKH XQLW LV connected properly. 3. The wires on the control board are loose. 0DNH VXUH WKH ZLUHV RQ WKH FRQWURO ERDUG DUH connected properly. 4. The switch board and control board wirings are disconnected.
Warranty www.zephyronline.com =HSK\U 9HQWLODWLRQ //& UHIHUUHG WR KHUHLQ DV ³ZH´ RU ³XV´ ZDUUDQWV WR WKH RULJLQDO FRQVXPHU SXUFKDVHU UHIHUUHG WR KHUHLQ DV ³\RX´ RU ³\RXU´ RI =HSK\U SURGXFWV WKH ³3URGXFWV´ WKDW VXFK 3URGXFWV ZLOO EH IUHH from defects in materials or ZRUNPDQVKLS DV IROORZV Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parWV LQFOXGLQJ /(' OLJKW EXOEV LI
PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
Guide d’utilisation, d’entretien et d’installation www.zephyronline.com Siena Pro ZSP-E36BS ZSP-E42BS ZSP-E48BS Model number: Serial Number: APR19.0301 © Zephyr Ventilation LLC.
www.zephyronline.
2-3 LISTE DU MATÉRIEL....................................................................................................................... 4 INSTALLATION Feuille de calcul pour le conduit............................................................................... Espace libre et hauteur de montage........................................................................... Options d’installation pour le conduit...................................................................................
www.zephyronline.com Mise en garde de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, communiquez avec le fabricant. b.
POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
Liste du matériel www.zephyronline.
= Longueur x Nombre utilisé Pièces de conduit Total 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit x( ) = pi x( ) = pi x( ) = pi x( ) = pi x( ) = pi 23 pi 7” circ. à rect. de 3-1/4" x 10", coude à 90º x( ) = pi 3-1/ 4” x 10” 30 pi embout mural rect.
Installation – Espace libre et hauteur de montage www.zephyronline.com Lorsqu’il possible de le faire, diminuez TOUJOURS le nombre de pièces et de changements de direction. Si un long tronçon de conduit est nécessaire, augmentez le diamètre du conduit de 10” à 12”. Si des changements de direction ou des adaptateurs sont nécessaires, installez-les le plus loin possible de l’ouverture et le plus éloigné possible l’un de l’autre. n. A mi . B x a m n. C mi .
N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de recirculation d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple.
3” 16 11/16” 11 5/16” 1 9/16” 35 7/8”, 41 7/8”, 47 7/8” Devant de la hotte 12 3/16” STANDARD min. ducted - 27 1/2” min. recirc. - N/A max. - 42” Z1C-00SP min. ducted - 45 min. recirc. - N/A max. - 78” 21 15/16” Côté de la hotte Entrée élec. 6 3/4” 6 9/16” 1” Installation – 6SpFL¿FDWLRQV GH OD KRWWH www.zephyronline.
Installation – 0RQWDJH GH OD KRWWH ! ATTENTION : Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. 1. Prenez la mesure entre la surface de la cuisinière et la base de la hotte; marquez la ligne A (min. 24” à partir du dessus de la cuisinière). L/C Support pour le recouvrement du conduit 2. Marquez la ligne centrale avec exactitude. 3. Marquez la ligne de hauteur de montage B (à 12-1/8” de la ligne A). 4.
Commandes - ,&21 &RPPDQGHV j HIÀHXUHPHQW www.zephyronline.com Mise en marche/Arrêt à retardement Choix de 5 vitesses Lumières : Allumer/Veilleuse/Éteindre Afficheur (vitesse, arrêt à retardement, nettoyage/changement des filtres) 1 MISE EN MARCHE/ARRÊT À RETARDEMENT Fonction de la touche de mise en marche - La touche permet d’allumer et d’éteindre toutes les fonctions de la hotte (ventilateurs et lumières). - La hotte se rappelle la dernière vitesse et le dernier niveau d’éclairage utilisés.
Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. Pour les taches plus tenaces, utilisez du produit dégraissant liquide. Après le nettoyage, vous pouvez polir les surfaces avec des produits de polissage à acier inoxydable non abrasifs pour redonner de l’éclat et du lustre aux surfaces.
0DLQWHQDQFH Lumières www.zephyronline.com Bandes de lumière LED Dans l’éventualité peu probable d’une défaillance de votre bande de LED, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la liste des pièces et accessoires à la page pour les références et les coordonnées. Pour remplacer la bande lumineuse à LED 5HWLUH] OHV ¿OWUHV j PDLOOHV HQ DOXPLQLXP 2. Retirez le panneau d’éclairage à l’aide de deux vis. 3. Débranchez le connecteur rapide du bandeau lumineux à LED. 4.
Certains codes et règlements limitent la quantité maximale de pi3/min qu’une hotte peut extraire. La ACT permet de contrôler la quantité maximale de pi3/min qu’évacuent un éventail de hottes Zephyr, éliminant la nécessité d’acheter un dispositif d’air d’appoint dispendieux. La ACT permet à l’installateur d’ajuster facilement la vitesse maximale du ventilateur à l’un des niveaux de pi3/min les plus fréquemment utilisés : 590 pi3/min ou 390 pi3/min.
Diagrammes des courbes caractéristiques des ventilateurs www.zephyronline.
15 Diagrammes des courbes caractéristiques des ventilateurs
6FKHPD 'H &LUFXLWV www.zephyronline.
Problème Cause Solution Après l’installation, l’appareil ne fonctionne pas. 1. Le bloc d’alimentation n’est pas allumé 1. 2. La ligne électrique et le raccord de câble ne sont pas correctement branchés 9pUL¿H] TXH OH EUDQFKHPHQW GH O¶DSSDUHLO D pWp IDLW correctement Les lumières fonctionnent, mais le ventilateur ne tourne pas. L’appareil vibre. Assurez-vous que l’alimentation du disjoncteur et de l’appareil est allumée 3. Les câbles du tableau de commandes sont desserrés. 3.
Garantie www.zephyronline.
ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire. Il vous permet de recevoir des avis concernant des modifications ou des rappels de produits.