Use, Care, and Installation Guide www.zephyronline.com Siena ZSI-E30AS ZSI-E36AS ZSI-E30AS-ES ZSI-E36AS-ES ZSI-E30AS-ES ZSI-E36AS-ES Model number: Serial Number: SEP15.0301 © 2015 Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet........................................ Mounting Height & Clearance................................. Ducting Options............................................................ Hood Specifications.................................................... Mounting the Range Hood....................................... Ductless Recirculating............................................... 5 6 7 8 9 10 FEATURES & CONTROLS ICON Touch Controls.....................................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
List of Materials www.zephyronline.
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight Equivalent number length x used = Total 3-1/ 4” x 10” 5 Ft. Rect. to 6” round transition x( ) = Ft. 3-1/ 4” x 10” 20 Ft. Rect. to 6” round transition 90 0 elbow x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. Ft. x( ) = Ft. 24 Ft. x( ) = Ft.
Installation – Mounting Height & Clearance www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible. A n. mi . B n i m .C x ma D n. mi . E n mi . F x ma Minimum mount height between range top to hood bottom should be no less than 26”. in. ” m x.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Front of Hood Side of Hood 10 1/2” 8 7/16” STANDARD min. ducted - 27 1/2” min. recirc. - 32” max. - 42” Z1C-00SI min. ducted - 46 1/2” min. recirc. - 50 1/2” max. - 79” 1 9/16” 12 3/8” 29 15/16”, 35 7/8” 21 15/16” Top of Hood 4 1/4” /4” 73 C/L 8 4 3/8” AC In 5/8” Installation – Hood Specifications www.zephyronline.
Installation – Mounting the Hood ! CAUTION: At least two installers are required due to the weight and size of the hood. 1. Measure from range top to hood bottom and mark line A. (26” minimum from range top). C/L Duct Cover Bracket 2. Plum and mark center line. 3. Mark mounting height line B. (1-5/16” from line A) 4. Mark mounting height line C. (13-1/8” from line A) 9-7/16" 5. Mark mounting spread from C/L on line B 12-3/4” 7. Fasten (2) M4 x 1-1/2” screws into studs on line C.
Installation – Ductless Recirculating www.zephyronline.com FOR MODELS ZSI-E30AS and ZSI-E36AS ONLY Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and recirculated back within the home.
Adjust 5 Speed Levels Lights On/Dim/Off Display (speed level, delay off, filter clean/change) 1 POWER / DELAY OFF BUTTON Power Button Function - Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights. Press Button again and the hood will turn back on at speed 4 and high lights level.
Features & Controls - ICON Touch Controls www.zephyronline.com 3 LIGHTS BUTTON - Lights are two levels, High and Low. - From off, press one time for High. Press again for Low. Press again to power lights off. 4 DISPLAY INDICATORS Mesh Filter Clean Reminder (always enabled) - After 30 hours of fan usage, the button indicator will begin to slowly blink indicating it is time to clean the mesh filters. - To reset: With hood off: hold the button for three seconds.
Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain. Do not use any product containing chlorine bleach.
Maintenance – Light Bulbs www.zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. ZSI-E30AS-ES & ZSI-E36AS-ES: Access light bulb by removing light bulb lens cover by 1 screw. FIG. B Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out.
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The wires on the control board are loose. 3. Make sure the wires on the control board are connected properly. 4. The switch board and control board wirings are disconnected. 4.
USE ONLY 13W, GU24 FLUORESCENT LIGHT BULBS. MODEL SPS T3 13GUS. ZSI-E30AS-ES ZSI-E36AS-ES Power consumption shown for default 650 CFM blower configuration VOLTS HZ MAX AMPS ACT 390 CFM - Fan Max. 393W @ 3.3A 120 60 1.2 ACT 290 CFM - Fan Max. 365W @ 3.0A CIRCUIT DIAGRAM YELL0W RED WHITE BLACK WHITE RED BLUE YELL0W WHITE BLUE WHITE AC-N BLACK MOTOR1 AC-L LAMP WHITE MOTOR2 TRANS AC-12V GREEN WHITE BLACK Wiring Diagram www.zephyronline.
DESCRIPTION PART# Replacement Parts Baffle Filter (each) 50200050 Halogen 50W Light bulb (each) Z0B-0020 Optional Accessories Recirculating Kit ZRC-00SI Replacement Charcoal Filter (each) Z0F-C091 Duct Cover Extension Kit Z1C-00SI Universal Make-Up Air Damper MUA008A ZSI-E30AS-ES & ZSI-E36AS-ES DESCRIPTION PART# Replacement Parts Baffle Filter (each) Fluorescent Bulb, GU-24, 13W (each) 50200050 Z0B-0036 Optional Accessories Duct Cover Extension Kit Z1C-00SI To order parts, visit us
Warranty www.zephyronline.
19
www.zephyronline.com PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. 20 | Alameda, CA 94502 | 1.888.880.