Installation Guide
9
1.  Measure from range top to hood bottom and mark line A. 
(26” minimum from range top).
2.  Plum and mark center line.
3.  Mark mounting height line B. (1-5/16” from line A)
4. Mark mounting height line C. (13-1/8” from line A)
5. Mark mounting spread from C/L on line B 12-3/4”
6.  Mark mounting spread from C/L on line C 9-7/16” 
7.  Fasten (2) M4 x 38 screws into studs on line C. Do not 
fasten screws all the way. Note: wood blocking may need 
to be added behind the drywall if no studs are present. 
Wall anchors may also be used but check local codes 
for compliance. Failure to use suitable wall anchors 
and screws to hold the weight of the hood could result 
in personal injury or damage to cooking surface or 
counter.
8. Install 8” round duct collar with backdraft damper to top of 
body of hood by (4) M4x8 at screws. 
9. If ducting hood through rear of hood body, cut access hole 
in wall and prepair ducting.
10. Hang hood onto screws and hand tighten. (FIG. A) Use 
the last M4 x 38 screws to further secure the hood to the 
wall from inside the hood on line B.
11. Center and attach duct cover bracket to wall below ceiling 
or sot using (2) M4 x 38 screws.
12. Position electrical outlet within the space covered by the 
telescopic duct covers and where it will not interfere with 
the round duct. (FIG. B)
13. *Install duct work and duct tape.
14. Power up hood and check for leaks around duct tape.
15. Place telescopic duct covers onto hood and extend inner 
(top) duct cover upwards and secure to duct cover bracket 
using (2) M4x8 screws. 
 *If using hood in recirculating mode you must secure air 
diverter plate onto wall before installing duct work and duct 
covers. Turn to page12 for more details.
A
B
C/L
13-1/8"
9-7/16"
C/L
26" mi n
Duct Cover
 Bracket
C
12-3/4"
1-5/16"
C
B
CAUTION: At least two installers ar
e
required 
due to the weight and size of th
e
hood.
!
WARNING:  Electrical  wiring  must  be  done  by  a  qualified  person(s)  in
accordance 
with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!