Use and Care Manual
Table Of Contents
18
Savona, Anzio, Ravenna, Roma Use, Care, and Installation Guide
ZSA, ZAN, ZRV, ZRO
WALL
CORE
Installation Instructions
1.  Purchase recirculating kit per the part number on 
the table.
2.  Secure air diverter plate to wall below duct cover 
bracket. Run 6” ducting from top of hood and 
secure to air diverter plate (FIG. C).
3.  ZAN: Remove aluminum mesh filters from hood. 
Secure charcoal filters to back side of aluminum 
mesh filter by 3 brackets (FIG C2).
4.  ZSA, ZRV, ZRO: Remove aluminum mesh filters from 
hood. Secure charcoal filter brackets to the hood 
body behind each mesh filters using the screws 
included in the recirculating kit. Clip charcoal 
filters onto each charcoal filter bracket (FIG. C1).
5.  Re-install mesh filters.
6.  Charcoal filters must be replaced every 120 hours 
of use (or approximately every 3 to 4 months based 
on an average of 1 - 2 hours of daily cooking time).
DO NOT WASH CHARCOAL FILTERS. Charcoal filters 
may need to be changed more often depending on 
cooking habits.
Recirculating Kit Installation (required if no ducting is used)
FIG. C
C.1
C.2