TROUBLESHOOTING PROCEDURES
Issue Cause What to do
After installation,
the unit doesn’t
ZRUN
1. The power source is not turned ON.  0DNHVXUHWKHFLUFXLWEUHDNHUDQGWKHXQLW¶V
power is ON.
 7KHSRZHUOLQHDQGWKHFDEOHORFNLQJFRQQHFWRU
is not connecting properly.
 &KHFNWKHSRZHUFRQQHFWLRQZLWKWKHXQLWLV
connected properly.
3. The switch board or control board wirings are
disconnected.
 0DNHVXUHWKHZLULQJVDWWKHVZLWFKERDUGDQG
control board are connected properly.
4. The switch board or control board is defective. 4. Change the switch board or control board.
/LJKWZRUNVEXW
blower is not
turning.
1. The blower cable is disconnected. 1. Connect the blower cable.
2. Debris or obstruction in motor. 2. Remove the debris or obstrunction.
3. Motor defective or possibly seized. 3. Change the blower.
4. Damaged capacitor. 4. Change the capacitor.
5. The switch board or control board is defective. 5. Change defective part.
The unit is
vibrating.
1. The blower is not secured in place. 1. Tighten the blower in place.
2. Damaged blower wheel. 2. Replace the blower.
3. The hood is not secured in place.  &KHFNWKHLQVWDOODWLRQRIWKHKRRG
The blower is
ZRUNLQJEXWWKH
lights are not.
1. The LED light strip connector is disconnected. 1. Connect the LED light strip connector.
2. Defective LED light strip. 2. Change the LED light strip.
3. The switch board or control board is defective. 3. Change the switch board or control board.
The unit turns on
by itself.
$VSRWOLJKWRUNLWFKHQODPSLVVKLQLQJGLUHFWO\
onto the switch controls.
1. The switch controls are light sensative. A
direct light source onto the switch controls
may disrupt switch functions.
The hood is
not venting out
properly.
1. Using the wrong size of ducting. 1. Change the ducting to at least 6” round or
higher.
2. Using the wrong type of ducting. Flexible ducting
FDQUHGXFHDLUÀRZE\XSWR
2. Change the ducting to solid rigid metal
ducting.
3. The hood might be hanging to high from the
FRRNWRS
 $GMXVWWKHGLVWDQFHEHWZHHQWKHFRRNWRSDQG
the bottom of the hood within 26” and 34”
range.
4. The wind from the opened windows or opened
GRRUVLQWKHVXUURXQGLQJDUHDDUHDႇHFWLQJWKH
ventilation of the hood.
4. Close all the windows and doors to eliminate
WKHRXWVLGHZLQGÀRZ
 %ORFNDJHLQWKHGXFWRSHQLQJRUGXFWZRUN  5HPRYHDOOWKHEORFNLQJIURPWKHGXFWZRUNRU
duct opening.
Troubleshooting